IEC 60335-1 Clause 22.32 Ceramic Material Fuchsine Spirit Pressure Test Apparatus – BONAD
Application:
It is used to determine whether ceramic materials are sintered tightly.
Test Principle:
The booster pump pressurizes the closed container with water to the standard required pressure, and the ceramic material is broken and immersed in an alkaline fuchsin solution with a pressure of not less than 15MPa. After a period of time, the product of the sample duration and the test pressure is about 180.
Main Technical Parameters:
Specification | Details |
---|---|
Required Gas Source | 0.2-0.8 MPa, 0.6 Nm³/min |
High Pressure | 0-20 MPa |
Measurement Accuracy | ±0.5% FS |
Pressure Holding Time | Arbitrarily set, in seconds |
Data Acquisition | High-speed acquisition card |
Peak Value Recording | Measurement and control software recording |
Test Station | 1 station |
Exhaust System | Semi-automatic |
Test Medium | Clean water |
Volume | 30 L |
Output Interface | ZG1/4 internal thread |
Explosion Box Size | 800 mm x 650 mm |
Control System | PLC (Programmable Logic Controller) |
Features:
- The ceramic fuchsine pressure test device adopts gas-liquid ratio control.
- The PLC control system and operating software can display the test process on the touch screen, detect pressure changes in real time, and output dynamic curves.