IEC 60079 Vertical Impact Test Equipment for Explosion-Proof Enclosures
The apparatus adopts a vertical drop-weight testing method. A hemispherical impact element falls freely from a specified height through a guide tube to generate accurate and repeatable impact energy. The stable structure and release system help ensure reliable testing results for IECEx and ATEX compliance testing.
The release system is available in both manual release and electromagnetic release configurations to meet different testing requirements.
It is widely used by testing laboratories, certification organizations, and manufacturers of explosion-proof electrical equipment.
Standards
The apparatus is designed according to the following standards:
- IEC 60079-0
- IEC 60079-0 Figure A.3
- IECEx Testing Requirements
- EN 60079 Series
- ATEX Related Test Requirements
The impact energy is calculated according to:
E = mgh
Where:
- E = Impact Energy
- m = Impact Mass
- g = Gravity Acceleration
- h = Drop Height
Applications
The IEC 60079-0 Vertical Impact Test Apparatus is suitable for:
- Explosion-proof enclosures
- Cable entry devices
- Ex cable glands
- Flameproof housings
- Hazardous-area electrical products
- Industrial Ex components
Typical application industries include:
- Explosion-proof equipment manufacturing
- IECEx laboratories
- ATEX compliance testing
- Oil & gas industry
- Petrochemical industry
- Mining industry
- Third-party testing laboratories
Features
IEC 60079-0 Compliant Design
Designed specifically according to IEC 60079-0 Figure A.3 impact test requirements.
Accurate Impact Testing
The vertical guide structure ensures stable and repeatable impact positioning.
Manual or Electromagnetic Release System
The apparatus supports both manual release and electromagnetic release methods for different testing applications.
Adjustable Impact Height
Impact height can be adjusted from 100mm to 2000mm for different impact energy requirements.
Heavy-Duty Structure
The reinforced steel frame and base plate provide excellent stability during testing.
Easy Operation
Simple mechanical design allows convenient installation and operation.
Customization Available
BONAD supports customized:
- Impact heights
- Fixtures
- Safety protection enclosures
- PLC control systems
- Automatic lifting systems
Technical Parameters
| Item | Specification |
|---|---|
| Product Name | IEC 60079-0 Vertical Impact Test Apparatus |
| Brand | BONAD |
| Model | BND-IEC60079-VI |
| Standard | IEC 60079-0 Figure A.3 |
| Test Method | Vertical Drop Weight Impact |
| Impact Element | Φ25mm Hemispherical Head |
| Impact Mass | 1kg |
| Impact Height | 100–2000mm Adjustable |
| Release Method | Manual Release / Electromagnetic Release |
| Guide Tube | Precision Guide Structure |
| Base Plate Size | 1000mm × 1000mm |
| Structure Type | Beam-Type Structure |
| Height Adjustment | Manual |
| Power Supply | AC 220V / 50Hz |
| Optional Power Supply | 110V / 60Hz |
Why Choose BONAD Vertical Impact Test Apparatus
BONAD focuses on IEC compliance testing equipment for laboratories, certification organizations, and industrial manufacturers worldwide.
Our IEC 60079-0 Vertical Impact Test Apparatus features stable performance, accurate impact testing, and reliable mechanical structure for long-term laboratory use.
We provide:
- Technical consultation
- Customized testing solutions
- Installation guidance
- Operation training
- After-sales support
BONAD also offers a complete range of testing equipment for explosion-proof, IP waterproof, environmental, mechanical, battery, and electrical appliance testing.
FAQ:
What is the IEC 60079-0 vertical impact test used for?
The test is used to evaluate the impact resistance and mechanical strength of explosion-proof products under specified impact conditions.
What products can be tested?
The apparatus is suitable for testing explosion-proof enclosures, cable glands, cable entry devices, and other Ex electrical products.
What release methods are available?
The apparatus supports both manual release and electromagnetic release configurations.
How is the impact energy determined?
Impact energy is calculated according to the impact mass and drop height using the formula E = mgh.
Can the impact height be customized?
Yes. BONAD can customize the impact height range and fixture system according to customer requirements.
Is the equipment suitable for IECEx and ATEX testing?
Yes. The apparatus is designed according to IEC 60079-0 requirements and is suitable for IECEx and ATEX related testing applications.
Does BONAD provide technical support?
Yes. BONAD provides technical consultation, installation guidance, operation training, and after-sales support.
Request a Quote
Looking for reliable IEC 60079-0 explosion-proof testing equipment?
BONAD provides professional testing solutions for IECEx and ATEX compliance laboratories worldwide.
Contact BONAD today for:
- Product quotation
- Technical consultation
- Customized solutions
- Detailed specifications
- Worldwide delivery