IEC 60335-1 Anti-Shock Probe Experiment Device – BONAD Electric Shock Probe Circuit Test Device
Standards:
This device rigorously adheres to global safety regulations, including:
- IEC 60335-1 Clause 8.1.4 (Household Appliances)
- IEC 60065:2014 Clause 9.1.1.2 (Audio/Video Equipment)
- Supports testing per IEC 60950 (IT Equipment) and IEC 61010 (Lab Instruments).
Applications:
- Quality Assurance: Validate electrical safety in appliances pre-market release.
- Certification Testing: Ensure compliance for IEC, UL, CE, and other certifications.
- R&D Safety Checks: Identify design flaws in prototypes.
- Production Line Testing: Rapidly verify insulation integrity in manufacturing.
- Educational Labs: Teach electrical safety protocols in engineering courses.
Features:
- Precision Voltage Generation
- Simulates 5V to 5kV fault conditions to replicate real-world shock risks.
- Intelligent Current Limiting
- Safeguards equipment and operators with auto-cutoff for excessive current.
- Probe-Based Testing
- Includes finger-simulation probes (e.g., test finger) to mimic human contact points.
- Multi-Test Modes
- Measures touch current, leakage current, insulation resistance, and ground bonding.
- Safety Interlocks
- Emergency stop button, safety shields, and circuit breakers for hazard prevention.
- Instant Hazard Detection
- Audible buzzer and visual alarm activate upon live-part contact.
- One-Touch Reset
- Press RESET to silence alarms and disconnect power immediately.
- Standards-Compliant Design
- Pre-configured for IEC 60335-1, IEC 60065, and related frameworks.
Technical parameters:
Applied standard | IEC 60335-1 |
Applied clause | Clause 8.1.4 |
Working voltage | AC 220V±10%, 50HZ±1% |
Electrode output the testing voltage | AC40-50V |
Working temperature | 0-40 |
Relative humidity: | ≤80% |
Environment | No shaking and no corrosive gas |
Operation steps
- Connect one electrode to the appliance’s live part and the other to the test probe.
- Power on the device and touch external parts with the probe.
- Alarm sounds + lights flash? → Live part detected.
- Press RESET to halt alarms and cut power.
Safety notice:
- Verify wire conductivity before use.
- Never place both electrodes on the same metal surface (avoids false alarms).
- Use insulated gloves to prevent operator shock.