Advanced ISO 15502 Refrigerator Performance Laboratory – Test Up to 6 Units Simultaneously
Standards:
Our laboratory adheres to international standards including:
- IEC 62552: Characteristics and test methods for household refrigerating appliances.
- ISO 15502: Standardized methods for evaluating household refrigeration appliances.
- SASO 2664: Regional compliance standards.
Application:
The refrigerator performance laboratory is designed according to relevant international test standards or some local standards, such as ISO 15502, IEC 62552, and is used to test the performance of refrigerators, refrigerators or freezers. It can test the refrigeration capacity, power consumption and many performance parameters of the test unit. This test chamber is usually used in product development and quality control departments and is a must-have facility for manufacturers and certification bodies.
Features:
Equipped with a programmable controller and a human-machine interface control device, our laboratory ensures seamless operation. High-precision data collectors gather test operation data which is then transmitted in real-time to the host computer for processing. The host computer not only displays but also stores, outputs, and prints comprehensive test reports.
Moreover, we offer customization of the test chamber to align with specific customer requirements or unique test standards.
Technical parameters:
Specification | Value |
---|---|
External Dimensions | 6200L × 3800W × 3400H |
Internal Dimensions | 6000L × 3600W × 3000H |
Door Dimensions | About 1200W × 2000H |
Observation Window | 1500W × 400H, double-layer insulating glass |
Moisture-Proof Lighting | LED lamp, 20W, 6 pairs |
Temperature Range | 0 ~ 50℃ ± 0.2℃ |
Humidity Range | 30% ~ 95% RH ± 3% |
Control Humidity Range | Between 10 ~ 45℃ |
Temperature Steady State Change Rate | ≤ ±0.5℃ /10h (assessed between 10 ~ 43℃) |
Control Temperature Range | 0 ~ 50℃ |
Control Temperature Accuracy | ±0.2℃ |
Temperature Measuring Element | PT100 platinum resistance, Class A, Qianye |
Temperature Control Table | UT35A |
Control Humidity Range | 30% ~ 95% RH |
Humidity Control Accuracy | ±3% RH |
Humidity Measuring Element | HMD80, Vaisala, relative humidity test method |
Humidity Control Table | UT35A |