IEC60695-2 Fire Hazard Needle Flame Test Apparatus

IEC60695-2 Fire Hazard Needle Flame Test Apparatus

IEC60695-2 fire hazard needle flame test apparatus 1.Needle Flame Test Euqipment meets IEC60695 2.Can measure kind of materials According to IEC60695, ZY3 Needle Flame Tester is applied in the production and quality control department of lighting instrument, hypopiesis electrical apparatus,...

Send InquiryChat Now
Product Details

IEC60695-2 fire hazard needle flame test apparatus


1.Needle Flame Test Euqipment meets IEC60695


2.Can measure kind of materials

According to IEC60695, ZY3 Needle Flame Tester is applied in the production and quality control department of lighting instrument, hypopiesis electrical apparatus, domestic appliance, machine electric appliance, electrical machine, power tool, electronic instrument, electrician instrument and technical equipment. Also, it is fit for the industry of insulation material, engineering plastics and solid combustible material.


Technical Parameters


Technical Parameters

Burner Angel

0°, 20°,45°

Flame Height

12±1mm

Needle burner

Height above 35mm, Stainless steel needle Φ0.9mm-Φ0.5mm

Standard Copper Block

0.58±0.01g

Check time

23.5±1S

Temperature Test

MAX1050°C ±0.1%

Thermocouple

RS (British), Type KΦ0.5, accuracy ±0.05%

Gas variety

Butane or purity above 95%,Propane

针焰试验仪.JPG

Installation and adjustment of the equipment

1: condition of Installation

a: the equipment should install in the table board and fume hoods,

b: Min. Size of the table board: Length 1400mm * Width 800mm * Height (600 to 800)mm

c: Boundary dimension: Length 1100mm * Width 700mm * Height 1300mm

d: the installation distance of the wall: >200mm will be better

e: Diameter of smoke vent: 100mm

f: Height of table-board keeps 600 to 800mm to convenience the operation

g: Independent test room with necessary exhaust system and fire protection equipment

h: Customer need to prepare the gas (Butane or purity above 95% Propane) and the hydrogen pressure reducing valve yourselves.


2: Adjustment

A: Leak test: check the gas circuit include Air source, Reducing Valve, whether the related adaptor is tightened

 Close the Pressure Regulating Valve, and open the Gas Cylinder

 Adjust the Hydrogen Pressure Reducing Valve smoothly, make the output pressure around 0.2MPa,

 Adjust the control panel of " Pressure Regulating Valve" and make the pressure gage not exceed 0.1MPa/1kg.

 Close the Gas cylinder, wait for 5 minutes, and check the of pressure's situation


FAQ

1.What about your quality?

Each equipment must be carry out 100% examination and test again before shipping


2.What is the MOQ ?

Most instruments support MOQ one set.


3.How long the delivery time ?

Generally most equipment will be 3-10days after we receive your payment or the order conformed ,please conform with us before you made an order .


4.What is the warranty of the products?

One year ,but we can provide you life long support .


5.What is the package?

Export standard Solid wooden case


6.What is the shipping way ?

We have stable forwarding agent for air and sea transportation ,and also express about DHL TNT etc , we will suggest you the best shipping way base on your requirement .


7.What is the payment term ?

T/T, Western Union,Money gram ,Paypal etc


8.Can we buy 1 pcs sample testing

Yes, we are glad to send 1pc for quality testing if we have stock of the model you required.


9.How to contact us ?

Address

 

 Shenzhen Bonad Instrument Co.,Ltd.

(Hong Kong Bonad Technology Limited)

A301 Hongdu Building ,

45 district, Baoan, Shenzhen City,

Guangdong Province 518100,China

Contact Person

Wendy qiu

Telephone#

86-0755-27337191

Fax#

86-0755-23721200

Email

wendy @szbonad.com

Mobile Phone#

+86 13418723413

Whatsapp#

+86 13418723413

Skype#

qiu-wendy

Working Hours

8:30~12:00  13:30~18:00 (from Monday to Friday)


test equipment.jpg

 

Hot Tags: iec60695-2 fire hazard needle flame test apparatus, China, manufacturers, suppliers, factory, buy, made in China
Inquiry